In a server room, the equipment and the uptime are the asset. We combine very early smoke detection with clean agent gas suppression that puts out a fire without water, residue or damage to live equipment.
The risks
What makes these buildings different
Electrical faults
Overheating cables, power supplies and UPS batteries can smoulder for a long time before visible smoke appears.
High airflow
Cooling systems dilute and move smoke around the room, which delays standard ceiling detectors.
Water damage
Sprinklers protect the building but destroy the equipment. In a server room, suppression has to be clean.
What we recommend
Systems suited to your site
Every site is different. We assess yours and recommend the right combination.
Aspirating smoke detection
Detects smoke particles at a very early stage, even in rooms with strong airflow.
Learn moreNovec 1230 and FM-200
Clean chemical agents that suppress fire within seconds and leave no residue on equipment.
Learn moreInergen
Inert gas suppression made from naturally occurring gases, suited to larger rooms.
Learn moreSystem integration
Automatic shutdown of air-conditioning and power, with alerts to your monitoring team.
Learn moreCompliance
Certified from design to handover
Gas suppression systems are designed, installed and commissioned by SAQCC Fire-registered professionals in line with South African National Standards, including SANS 14520 for clean agent systems, and serviced every six months.
- Design, installation and commissioning certificates
- System logbook and device layout drawings
- Six-monthly servicing with reminders and service certificates
Request a quote or book a service today.
Tell us about your site and we’ll recommend the right system, schedule and paperwork.
Frequently asked questions
Is gas suppression safe if people are in the server room?
When correctly designed, clean agent systems are suitable for normally occupied spaces. Alarms, a discharge delay and an abort control give people time to leave before the agent is released.
Which is best for a server room: Novec 1230, FM-200 or Inergen?
All three protect electronics without leaving residue. The right choice depends on the room size, space for cylinders, environmental preferences and budget. We assess the room and recommend the best fit.
Does the room need to be sealed?
Yes. Gas suppression works by holding the agent at the right concentration for a set time, so we check the room for openings and leaks and seal them as part of the installation.